Flame Rod - MVTA Burner, Cremation Retort (R6007)
Flame Rod - MVTA Burner, Cremation Retort (R6007)
Couldn't load pickup availability
Ordering 10 or more? Contact NCIS for a volume quote.
U.S.-manufactured flame rectification rod for cremation retort burner flame detection. Use the measurements below to compare this standard U.S. Ignition build with the part in hand.
Identification measurements
| Manufacturer part number | R6007 |
|---|---|
| Mounting thread | 1/4-18 NPT |
| A — overall/reference length | 5.29 in |
| B — length below the mount | 3.25 in |
| Hex size | 5/8 in |
| Terminal thread | 6-32 NC |
| Lower insulator length | 0.28 in |
| Electrode diameter | 0.187 in |
How to compare: Verify the mounting thread first. In the manufacturer drawing, A is the overall/reference length and B is the length below the mounting reference. Also compare the hex, terminal, lower-insulator length, electrode diameter. Do not rely on a product photo or printed part number alone; U.S. Ignition offers custom labeling and alternative lengths.
Verified cross-references
Auburn FRS-4 (3.25 in) · Eclipse 13093-3
U.S. Ignition states that its igniters and flame rods use 96% alumina ceramic and Kanthal D electrodes and are 100% tested before shipment.
Keep one on the shelf — a failed flame rod can lock out the burner.
Share